3. Same method as No. 2 except that the permanganate solution is added to the acidified sample when cold, and digestion is continued five minutes after the sample reaches the boiling point. The advantage of this method is that there is included the oxygen-consuming power of the volatile matter present in some sewages and sewage effluents, which is driven off by heat and thus escapes when the test is made in accordance with procedures 1 and 2.
4. Same method as No. 3 except that the period of digestion is 10 minutes.
5. Digestion of the sample after the acid and permanganate solutions are added is carried out abroad, especially in England, at approximately the room temperature, apparently to guard against decomposition of permanganate in the presence of high chloride, for periods of three minutes, fifteen minutes, and four hours; many observers record the oxygen consumed after all three periods, while some record the result only for the four-hour period. At the end of the period of digestion, add 0.5 cc. of potassium iodide solution to discharge the pink color; mix; titrate the liberated iodine with thiosulfate until the yellow color is nearly destroyed, then add a few drops of starch solution and continue titration until the blue color is just discharged. The number of cubic centimeters of potassium permanganate solution in excess of the number of cubic centimeters of sodium thiosulfate solution is equal to parts per million of oxygen consumed.
6. Digestion in alkaline solution is preferable to digestion in acid solution for brines or waters high in chlorine. Place in a flask 100 cc. of the sample, or if it is of high organic content a smaller portion diluted to 100 cc. Add 0.5 cc. of sodium hydroxide solution and 10 cc. of standard potassium permanganate and digest exactly 30 minutes. Remove the flask, add 5 cc. of sulfuric acid and 10 cc. of the standard ammonium oxalate, and titrate with the standard potassium permanganate as in the acid digestion.
RESIDUE ON EVAPORATION.
TOTAL RESIDUE.
Ignite and weigh a clean platinum dish, and measure into it 100 cc. of the thoroughly shaken sample. Evaporate to dryness on a water bath. Then heat the dish in an oven at 103° C. or 180° C. for one hour. Cool in a desiccator and weigh. The temperature of drying should be mentioned in the report. The increase in weight gives the total solids or residue on evaporation. If 100 cc. of the sample was taken this weight expressed in milligrams and multiplied by 10 is equal to parts per million of residue on evaporation. The residue from waters low in organic matter but relatively high in iron may be used, as a matter of convenience, for the determination of iron.
FIXED RESIDUE AND LOSS ON IGNITION.
The residue from sewages and waters high in organic matter may be ignited to burn off the organic matter, which, with some volatile inorganic matter, constitutes the loss on ignition.
Procedure.—Ignite the residue in the platinum dish at a low red heat. If great accuracy is desired this should be done in an electric muffle furnace or in a radiator, which consists of a platinum or a nickel dish large enough to allow an air space of about half an inch between it and the dish within it, the inner dish being supported by a triangle of platinum wire laid on the bottom of the outer dish. A disc of platinum or nickel foil large enough to cover the outer dish is suspended over the inner dish to radiate the heat into it. The larger dish is heated to bright redness until the residue is white or nearly so. Allow the dish to cool, and moisten the residue with a few drops of distilled water. Dry the residue in the oven, cool in a desiccator, and weigh. The fixed residue on evaporation is the difference between this weight and the weight of the dish.
The loss on ignition is the difference between the total residue on evaporation and the fixed residue on evaporation.
If the odor and color on ignition of some residues give helpful clues to the character of the organic matter record them.
SUSPENDED MATTER.
DETERMINATION WITH GOOCH CRUCIBLE.
Reagent.—Prepare a dilute cream of asbestos fibre which has been finely shredded, thoroughly ignited, treated with strong hydrochloric acid for at least 12 hours, and washed with distilled water till free from acid.
Procedure.—1. Prepare a mat of the asbestos fibre 1/16 inch thick in a Gooch crucible. Dry it in an oven at 103 or 180° C., cool and weigh. Filter 1,000 cc. of samples having a turbidity of 50 parts per million or less. If the turbidity is higher use sufficient water to obtain 50 to 100 mg. of suspended matter. Dry for one hour at 103 or 180° C., cool and weigh. Report the temperature at which the residue was dried. If 1,000 cc. is filtered the increase in weight expressed in milligrams is equal to parts per million of suspended matter.
DETERMINATION BY FILTRATION.
The difference between the total solids in filtered and unfiltered portions of a sample may be used as a basis for calculating suspended matter.
DETERMINATION OF VOLUME.
The determination of the volume of suspended matter in sewages has received considerable attention abroad. Imhoff recommends the use of conical glass vessels holding 1 liter with the lower portions graduated in cubic centimeters. Others recommend centrifuges with sediment tubes.
FIXED RESIDUE AND LOSS ON IGNITION.
Treat the total residue from a filtered sample in the same manner as described for the total residue, and obtain the loss on ignition due to dissolved matter, and by difference the loss on ignition due to suspended matter.
HARDNESS.
A water containing certain mineral constituents in solution, chiefly calcium and magnesium, which form insoluble compounds with soap, is said to be hard. Carbon dioxide in water increases the solubility of calcium and magnesium carbonates, forming bicarbonate. If carbon dioxide is removed from the water by boiling the bicarbonate is decomposed and calcium and magnesium are partly precipitated. The proportion of calcium or magnesium carbonate that a water can hold in solution depends on the concentration of carbon dioxide, which in turn depends on the temperature of the water and the proportion of carbon dioxide in the atmosphere with which the water has been in contact. Consequently, when the carbon dioxide is removed from the water by boiling or otherwise the carbonates of calcium and magnesium are partly, but not completely, precipitated, and the hardness of the water is thus diminished and the water is softened to the extent to which these substances are precipitated. The hardness thus removed is called temporary hardness. The hardness which still remains after boiling is due mainly to calcium and magnesium in equilibrium with sulfate, chloride, and nitrate, and residual carbonate, and it is called permanent hardness. Non-carbonate hardness is the hardness caused by sulfates, chlorides, and nitrates of calcium, magnesium, iron, and other metals that form insoluble soaps.
TOTAL HARDNESS BY CALCULATION.
The most accurate method of ascertaining total hardness is to compute it from the results of determinations of calcium and magnesium in the sample. (See methods, pp. 57–58.) Iron and other metals must be included in the calculation if they are present in significant amounts. Total hardness as CaCO_{3} equals 2.5 Ca plus 4.1 Mg.
TOTAL HARDNESS BY SOAP METHOD.
The determination of hardness by the soap method roughly approximates the amount of calcium and magnesium in a water, though it actually measures the soap-consuming power of the water.